Sign In | Join Free | My isp.org.cn |
|
Brand Name : kimoems
Model Number : Refer to parameters
Certification : CE
Place of Origin : China
MOQ : 1pc
Payment Terms : T/T
Mian Input Rate Voltage : 200/208/220VAC(L-L)
Mian Input Voltage Range : 166 ~ 261VAC(L-L) full load; 125 ~ 166VAC(L-L) power derate from 100% to 75%
Power Range : 10kVA or 15kVA or 20kVA or 30kVA or 40kVA
Operation : 3P/3P, Online double conversion
Applications : Government, Finance, IT, Education, Transportation, Broadcasting, Medical, Energy, etc.
Characteristics : 7 inch touch LCD with IoT functions. High power density, small volume. High reliability and environment adaptability. UPS with internal batteries maximum support for 80 PCS batteries. Standard configuration for mains input/output, bypass, maintenance bypas
(208V) 10~40kVA 3 Phases Tower UPS Internal 7/9Ah Modular Battery Strips
Product Introduction
Parameters
Model | TT010B-L-40 | TT015B-L-40 | TT020B-L-40 | TT030B-L-80 | TT040B-L-80 |
TT010L-L | TT015L-L | TT020L-L | TT030L-L | TT040L-L | |
Rate Power | 10kVA | 15kVA | 20kVA | 30kVA | 40kVA |
Main input | |||||
Input | 3P5W (3P+N+PE) | ||||
Rate Voltage | 200/208/220VAC(L-L) | ||||
Rate Freq. | 50/60Hz | ||||
Input PF | >0.99 | ||||
Current distortion | THDi<3% (100% Linear load) | ||||
Voltage range | 166 ~ 261VAC(L-L) full load; 125 ~ 166VAC(L-L) power derate from 100% to 75% | ||||
Freq. range | 40-70Hz | ||||
Battery | |||||
Rate voltage | ±120VDC | ||||
Model | UPS with internal batteries,12VDC/7~9Ah | ||||
UPS for external batteries,Settable | |||||
Internal BAT Quantity | 40PCS | 80PCS | |||
External BAT Quantity | Depend on external battery, 40PCS | ||||
Charging capacity | 20%*Pout | ||||
Charging accuracy | ±1% | ||||
Bypass | |||||
Rate voltage | 200/208/220VAC(L-L) | ||||
Voltage range | Range: -40%~ +25%, Settable, default -20%~ +15% | ||||
Frequency range | 50/60Hz, Settable: ±1Hz, ±3Hz, ±5Hz | ||||
Inverter | |||||
Rate voltage | 200/208/220VAC(L-L) | ||||
Rate Freq. | 50/60Hz | ||||
Output PF | 1 | ||||
Voltage accuracy | ±1.0% | ||||
Load response | <5% (20% - 80% -20% step load) | ||||
Recovery time | < 20ms (0% - 100% -0% step load) | ||||
Output THDu | <1% (linear load), <5% (non-linear load according to IEC 62040-3) | ||||
Overload | 110%, 1 hour; 125%, 10 mins; 150%, 1 min; >150%, 200ms | ||||
Frequency accuracy | 0.01% | ||||
Synchronize window | Settable, ±0.5Hz~±5Hz, default ±3Hz | ||||
Slew rate | Settable, 0.5Hz/S~3Hz/S, default 0.5Hz/S | ||||
Crest factor | 3:01 | ||||
Phase Accuracy | 120°±0.5° | ||||
System | |||||
Efficiency | Normal Mode up to 94%; Battery Mode up to 94% | ||||
Display | LED + 7 inch touch LCD | ||||
Certification> Safety | IEC62040-2; IEC62040-1, IEC60950-1 | ||||
Certification> EMS | IEC62040-4-2(ESD); IEC61000-4-2(RS); IEC61000-4-3 (EFT); IEC61000-4-5 (Surge) | ||||
IP degree | IP20 | ||||
Configuration | USB, RS232, RS485, Dry contact, Air filter | ||||
Option | SNMP card, AS400 card, Parallel kit, LBS, Cold start | ||||
Environment | 0-40°C (operation); -25°C~70°C (storage); 0-95% (Humidity, non-condensing) | ||||
Dimension (W*D*H) mm |
|||||
Internal BAT | 250*828*708 | 350*823*1200 | |||
External BAT | 250*530*650 | 250*782*650 | |||
Weight(kg) | |||||
Internal BAT | 63 | 90 | |||
External BAT | 43 | 53 | 66 | 72 | |
Statement: The products will continue to be innovative and optimized, which may lead to asynchronized updates of the actual product and promotional materials. Therefore, this document is for reference only and does not constitute any offer or commitment. |
![]() |
208V 10~40kVA 3 Phases Online Tower UPS Power Supply 7/9Ah Modular Battery Strips Images |